Event Id | 20226 |
Source | RasClient |
Description | ROUTERLOG_CORR_ID = |
Event Information | According to Microsoft : Cause : This event is logged when the user dialed a connection named which has been terminated. Resolution : Reconnect RAS connections To determine how to fix this error condition, examine the error code reported in the event message text. The error code is displayed in decimal numbers. The event message can report the following error codes:
Message: The connection was terminated because of idle timeout. This error occurs when the connection has been disconnected because the remote user's remote access session has been idle for a period of time greater than the idle timeout setting. This also results in the generation of event ROUTERLOG_CLIENT_AUTODISCONNECT. The timer can be configured on the client computer and on the server running NPS. To configure remote connection timeout:
Message: The modem (or other connecting device) was disconnected due to link failure. This error appears when the modem (in the case of dial-up or broadband connections) or tunnel (in the case of VPN connections) is disconnected due to a network failure or a failure in the physical link to the modem. The following are possible reasons for the failure.
Message: The connection was terminated because user logged off. The RAS connection was terminated because the user logged off of the Windows session in which the connection was active. Log on and make the RAS connection again. Error 831 (ERROR_FAST_USER_SWITCH) The connection was terminated because user switch happened. There are multiple login sessions on the user's computer. The user switched from a login session with an active RAS connection to another session. This resulted in the termination of the connection. Switch back to the original session and make the RAS connection again. Error 832 (ERROR_HIBERNATION) Message: The connection was terminated because of hibernation. The user put the computer into hibernation mode while the RAS connection was active. This resulted in the termination of the connection. The user lost connectivity to the network upon recovery from hibernation. Make the RAS connection again. Error 833 (ERROR_SYSTEM_SUSPENDED) Message: The connection was terminated because the system got suspended. The user's computer went into standby mode due to inactivity. This resulted in the termination of the connection. The user lost connectivity to the network. Make the connection again. Error 834 (ERROR_RASMAN_SERVICE_STOPPED) Message: The connection was terminated because Remote Access Connection manager stopped. If the Remote Access Connection Manager service is not already running, start the service from the Services console. Right-click the service, and then select Start . Note that administrative credentials are required to start the service. The Remote Access Connection Manager service is also started automatically when a RAS connection is dialed. The user stopped the Remote Access Connection Manager service. Check the status of the service in the Services console. To access the Services console:
To verify that the remote access server can accept connections, establish a remote access connection from a client computer. To create a VPN connection:
|
Reference Links | Event ID 20226 from RasClient |