Event ID - ASA-3-114017

Message CodeASA-3-114017
SeverityError
DescriptionFailed to get link status in 4GE SSM I/O card (error error_string).
syslog_id—Message identifier
error_string—Describes either an I2C serial bus error or a switch access error, which is a decimal
error code. The following are the I2C serial bus errors:
• I2C_BUS_TRANSACTION_ERROR
• I2C_CHKSUM_ERROR
• I2C_TIMEOUT_ERROR
• I2C_BUS_COLLISION_ERROR
• I2C_HOST_BUSY_ERROR
• I2C_UNPOPULATED_ERROR
• I2C_SMBUS_UNSUPPORT
• I2C_BYTE_COUNT_ERROR
• I2C_DATA_PTR_ERROR
ExplanationThis message is displayed when the system fails to delete the multicast address in an 4GE SSM I/O card due to either an I2C error or a switch initialization error.
User ActionPerform the following steps:
1. Log and review the messages and the errors associated with the event.
2. Reboot the software running on the system.
3. Power cycle the box. When you turn off the power, make sure you wait several seconds before turning the power on.