Event ID - 9

Event Id9
SourceAFCNT4
DescriptionSCSI device timeout...
Event Information
This message from newsgroup may help you:
--------------------------------------------------------------------------------
SOLUTION:
1. ugrade FC drivers for both servers to 2.0.25.44 named AFC9XXX.SYS, After upgrading please apply n_dgto.reg file to setup adapter to work in fabric. Then reboot. After reboot check if this driver is now running for HBAs (in SCSI devices applet)

2. check if your VA7400 running HP18 firmware and battery firmware 4.3

3. everything should be in fabric (if you use switches of course). If you use brocade switches you should see only F-ports in its 'switchshow' output

4. if you want VA LUNs to have failover capability do not forget, if you use VA security, to assign 'WC' (not only 'W') permissions to cluster LUNs.
--------------------------------------------------------------------------------.
Reference LinksServers hang with event id 9