Event ID - 301

Event Id301
SourceCOMTI
Description301) COM Transaction Integrators state machine dispenser was unable to allocate a state machine object
Progress Code: 2
HRESULT: 0x80040111
Event InformationCOMTI components that use an LU 6.2-type Remote Environment may fail under load and log events 103, 300, and 301 in the application event log. 
CAUSE:
Under load, multiple COMTI client requests may be received at or near the same time. If this occurs when COMTI tries to load the APPC transport DLLs (wappc32.dll and wincsv32.dll), a timing issue may occur, which causes COMTI to return an exception to the client and to log the events that are listed in the "Symptoms" section. 
RESOLUTION:
To resolve this problem, obtain the latest service pack for Host Integration Server 2000.
Reference Links COMTI May Log Events 103, 300, and 301 When Under Load