Event ID - 2178

Event Id2178
Event SourceServer Administrator
DescriptionThe controller battery Learn cycle has timed out.
More InformationCause :
The controller battery must be fully charged before the Learn cycle can begin. The battery may be unable to maintain a full charge causing the Learn cycle to timeout. Additionally, the battery must be able to maintain cached data for a specified period of time in the event of a power loss. For example, some batteries maintain cached data for 24 hours. If the battery is unable to maintain cached data for the required period of time, then the Learn cycle will timeout.
Resolution :
Replace the battery pack as the battery is unable to maintain a full charge.