Event ID - 585

Event Id585
Event SourcePerc2Pro
DescriptionSmart FPT exceeded
More InformationAccording to Dell:
Cause:

A disk on the specified controller has received a SMART alert (predictive failure) indicating that the disk is likely to fail in the near future

Resolution:
Replace the disk that has received the SMART alert. If the array disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing an array disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may cause data loss.
Reference Linksevent id:585 and source:Perc2Pro

Catch threats immediately

We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.

See what we caught

Did this information help you to resolve the problem?

Yes: My problem was resolved.
No: The information was not helpful / Partially helpful.