Event ID - 570

Event Id570
Event SourceAspiPro
DescriptionPredictive Failure reported. If this disk is part of a redundant virtual disk, select the `Offline' option and then replace the disk. Then configure a hot spare and it will start the rebuild automatically. If this disk is a hot spare, select the `Prepare to Remove' option and then replace the disk. If this disk is part of a non-redundant disk, you should back up your data immediately. If the disk fails, you will not be able to recover the data.
More InformationAccording to Dell:
Cause:

The array disk is predicted to fail. Many array disks contain Self Monitoring Analysis and Reporting Technology (S.M.A.R.T.). When enabled, SMART monitors the health of the disk based on indications such as the number of write operations that have been performed on the disk.

Resolution:
Replace the array disk. Even though the disk may not have failed yet, it is strongly recommended that you replace the disk. Review the message text for additional information.
Reference Linksevent id:570 and source:AspiPro

Catch threats immediately

We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.

See what we caught

Did this information help you to resolve the problem?

Yes: My problem was resolved.
No: The information was not helpful / Partially helpful.