Event ID - 509

Event Id509
Event SourcePerc2Pro
DescriptionVirtual Disk degraded
More InformationAccording to Dell:
Cause: 1

This event message occurs when a physical disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt.
Cause: 2
A physical disk in the array has been removed

Resolution: 1
Configure a hot spare for the virtual disk if one is not already configured. Rebuild the virtual disk. When using a PERC 2/SC, 2/DC, 3/SC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, 4e/Di, or CERC ATA100/4ch controller, rebuild the virtual disk by first configuring a hot spare for the disk, and then initiating a write operation to the disk. The write operation will initiate a rebuild of the disk.
Resolution: 2
If a physical disk was removed from the array, either replace the disk or restore the original disk. You can identify which disk has been removed by locating the disk with a red "X" in the Array Manager console's tree view. Perform a rescan after replacing the disk.
Reference Linksevent id:509 and source: Perc2Pro

Catch threats immediately

We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.

See what we caught

Did this information help you to resolve the problem?

Yes: My problem was resolved.
No: The information was not helpful / Partially helpful.