Event ID - PIX-6-210022

Message CodePIX-6-210022
SeverityInformation
DescriptionLU missed number updates
ExplanationStateful Failover assigns a sequence number for each record sent to the standby unit. When a received record sequence number is out of sequence with the last updated record, the information in between is assumed lost and this error message is sent.
User ActionUnless there are LAN interruptions, check the available memory on both Cisco ASA units to ensure that there is enough memory to process the stateful information. Use the show failover command to monitor the quality of stateful information updates.
Reference Links

Catch threats immediately

We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.

See what we caught

Did this information help you to resolve the problem?

Yes: My problem was resolved.
No: The information was not helpful / Partially helpful.