Event ID - PIX-3-216003

Message CodePIX-3-216003
SeverityError
DescriptionUnrecognized timer timer_ptr , timer_id received by task_string in function at line: line_num
ExplanationThis message is displayed when an unexpected timer event woke up the task and the task does not know how to handle the event. A task can register a set of timer services with the scheduler. If any of the timers expire, the scheduler wakes up the task to take action. This message is generated if the task is woken up by an unrecognized timer event. An expired timer, if left unprocessed, wakes up the task continuously to make sure it is processed, and this is undesirable. This should not occur under normal conditions. If This message is displayed, it does not necessarily mean the box is unusable, but something unusual has occurred and needs to be investigated.
timer_ptr—Pointer to the timer
timer_id—Timer identifier
task_string—Custom string passed by the task to identify itself
function—The function that received the unexpected event
line_num—Line number in the code
User ActionCopy the error message and submit it to Cisco TAC along with the configuration and any details about the events leading up to this error.