Message Code | PIX-1-104001 |
Severity | Alert |
Description | (Primary) Switching to ACTIVE (cause: string). |
Explanation | Explanation Both instances are failover messages. These messages usually are logged when you force the pair to switch roles, either by entering the failover active command on the standby unit, or the no failover active command on the active unit. (Primary) can also be listed as (Secondary)
for the secondary unit. Possible values for the string variable are as follows: • state check • bad/incomplete config • ifc [interface] check, mate is healthier • the other side wants me to standby • in failed state, cannot be active • switch to failed state |
User Action | If the message occurs because of manual intervention, no action is required. Otherwise, use the cause reported by the secondary unit to verify the status of both units of the pair. |
Reference Links |