Message Code | ASA-7-723006 |
Severity | Debugging |
Description | WebVPN Citrix SOCKS errors. |
Explanation | An internal Citrix SOCKS error has occurred on the security appliance. |
User Action | Verify that the Citrix ICA client is working properly. In addition, check the
network connection status between the Citrix ICA client and the security appliance, paying attention
to packet loss and so forth. Resolve any abnormal network conditions. If this message is still
received, contact Cisco TAC and provide the following information: • Output from the show mem detail command when the problem is occurring. • Output from the show blocks all when the problem is occurring. • Steps to reproduce the problem. • Complete text of all associated messages. |
Reference Links |