Event ID - ASA-4-413002

Message CodeASA-4-413002
SeverityWarning
DescriptionModule in slot slotnum is not able to reload. Module Error: errnum message
ExplanationThe module in slotnum was not able to comply with a request from the ASA system module to reload. It may be performing a task that could not be interrupted, like a software upgrade. The errnum and message text describes the reason why the module could not reload, and the recommended action.
User ActionWait for the task on the module to complete before reloading the module, or use the session command to access the module's CLI and stop the task that's preventing the module from reloading.