Message Code | ASA-3-114013 |
Severity | Error |
Description | Failed to set mac address table in 4GE SSM I/O card (error error_string). |
Explanation | This message is displayed when the system fails to set the MAC address table in an 4GE SSM I/O card due to an I2C error or a switch initialization error. syslog_id—Message identifier error_string—Describes either an I2C serial bus error or a switch access error, which is a decimal error code. The following are the I2C serial bus errors: I2C_BUS_TRANSACTION_ERROR I2C_CHKSUM_ERROR I2C_TIMEOUT_ERROR I2C_BUS_COLLISION_ERROR • I2C_HOST_BUSY_ERROR I2C_UNPOPULATED_ERROR I2C_SMBUS_UNSUPPORT I2C_BYTE_COUNT_ERROR I2C_DATA_PTR_ERROR |
User Action | Perform the following steps: 1. Log and review the messages and the errors associated with the event. 2. Reboot the software running on the system. 3. Power cycle the box. When you turn off the power, make sure you wait several seconds before turning the power on. 4. If the problem persists, contact Cisco TAC. |