Event ID - 9001

Event Id9001
SourceMicrosoft Operations Manager
DescriptionDescription: MOM Engine of Management Group <management group name> failed to start in the allocated time.
Event InformationCause :
Windows Management Instrumentation (WMI) is not allowed to start the Citrix WMI Service at the same time as the MOM service is starting up because the Service Control Manager database is locked. If the Citrix WMI Service fails to start, a rule in the Citrix Management Pack will fail to register its WMI event query and as a result, MOM cant successfully start its configuration group. Due to this, the MOM service shuts itself down.
RESOLUTION
In the MOM 2005 Administrator Console, navigate to Microsoft Operations Manager (<groupname>)\Management Packs\Rule Groups\Citrix MetaFrame\MetaFrame Server Rules\ Event Rules. For each of the below six rules, right-click the rule, choose properties, and then clear "This rule is enabled." This will disable the rule.

Zone elections: subscribe to zone election events
Zone elections: check rate of zone elections
Zone elections: rate of elections is high
Disconnections: subscribe to sessions disconnection events
Disconnections: check rate of disconnections
Disconnections: rate of session disconnects is high.
Reference LinksMOM Agent Fails to Start on a Computer Running MetaFrame XP or Presentation Server

Catch threats immediately

We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.

See what we caught

Did this information help you to resolve the problem?

Yes: My problem was resolved.
No: The information was not helpful / Partially helpful.