Event Id | 5754 |
Source | BizTalk Server 2004 |
Description | The adapter failed to transmit message going to send port "sendportname". It will be retransmitted after the retry interval specified for this Send Port. Details: "Unknown Error Description ". |
Event Information | "According to Microsoft: Cause: This error is a generic exception that could occur for several reasons. 1. A problem in error reporting when there is a problem with the orchestration. You might have an error that escapes proxy validation. An example is a type mismatch when a response message is constructed and sent. The type mismatch becomes a deserialization problem in the proxy before sending the message. A COM exception is thrown but the exception message is not reported correctly by the BizTalk Server Web proxy. 2. A common cause is when you do not have the necessary security configuration on the box. 3. A possibility is when the ASP NET process does not have permission to the access the emp% directory. By default anonymous access is turned off for the published Web service for security reasons. You may see the above error if you are using Internet Explorer to test your Web service. 4. This error may occur if there is a problem with the target Web service or if the default timeout setting is not long enough. User Action : 1. Check the Event Viewer or HAT for details. You can also get more specific exception for debugging purposes by enabling debugging for your published Web service. 2. Verify that you have the correct permissions set if you are getting an access denied error to the emp% directory. If you do not turn on the anonymous access, ensure that you supply valid credentials when calling the published Web service. If you wish to turn on anonymous access for your Web service, you can do that using IIS manager. 3. Use a simple client, such as a C# or Visual Basic .NET client, to submit data to your Web service. You must have the BizTalk Isolated Host installed and is not trusted. Also make sure that you have enabled receiving HTTP and SOAP Handlers. For more information, see ""Enabling BizTalk Web Services"" in the documentation. 4. Also verify that the receive location is configured correctly. For more info |
Reference Links | The "%1" adapter is suspending an outbound message going to destination URL:"%2". Details:"%3"
FIX: You receive a event ID 5743 message when you use the BizTalk Adapter for MQSeries 2.0 to send messages to an IBM MQSeries server Microsoft BizTalk Server 2004 |
Catch threats immediately
We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.