Event ID - 5224

Event Id5224
SourceBizTalk Server 3.0
DescriptionUnexpected end of document. It is not a new document and the dissassembly is incomplete.
Event Information According to Microsoft :
CAUSE :
The XML disassembler has encountered a message that is incomplete either according to the schema or the XML document itself is incomplete.

SOLUTION :
Verify that the input message is complete and contains a valid XML document. Use the instance validation tool from within the BizTalk Server solution. Open the XML document using Internet Explorer to check the XML syntax.
Reference LinksEvent id: 5224 Source id:BizTalk Server 3.0

Catch threats immediately

We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.

See what we caught

Did this information help you to resolve the problem?

Yes: My problem was resolved.
No: The information was not helpful / Partially helpful.