Event Id | 4216 |
Source | COM+ |
Description | An unexpected error was returned by the MSMQ API function indicated. The following error message was retrieved from MSMQ. MQSendMessage : A cryptographic function has failed. Server Application ID: {B8BF4125-DE72-4A05-ACD5-EF181587084E} Server Application Name: MyApplication Error Code = 0xc00e0030 : COM+ Services Internals Information: File: .\channelmanager.cpp, Line: 388 Data: 0000: 50 00 55 00 42 00 4c 00 P.U.B.L. [...] |
Event Information | When you try to create a Queued Component (QC) from a client application, you may receive the "Object required" error message in Microsoft Visual Basic. The application event log shows an entry similar to the above. RESOLUTION : To resolve this problem, perform the following steps: In Control Panel, click Message Queuing. On the Security tab, click Renew internal certificate. MORE INFORMATION : This problem occurs under the following circumstances: The COM+ Application proxy has an Authentication level higher than None. This value is taken from the COM+ application when the application is exported. A domain user is making the QC call. The identitys certificates are not registered. If you do not need to use Authentication, perform the following steps: On the COM+ Application that is marked as Queued, set the Authentication level to None. Re-export the Application proxy to the client computers. |
Reference Links | Event ID 4216 "Object required" When You Create a Queued Component Event ID 4216 When You Invoke Queued Components |