Event ID - 24

Event Id24
SourceHIPAA EDI Subsystem
DescriptionError encountered: ERROR (33), interchange 10018 :
The time format is not valid. Contact the sender.
source format: [5 00401 ,X12-4010]
source document: [(unknown)]
source segment: [data#0,def#3,tag=GS ,name=Functional Group Header]
source element: [def#5,elm#5,comp#0,tag=337,name=Time], value: [14445271], incorrect length. Time of type [TS] must be formatted as [HHMM[SS]] (seconds are optional) (msgnr:0 segnr:0)(line:2 pos:37 filepos:144)
Event InformationAccording to Microsoft:
CAUSE:
This problem occurs if your HIPAA document has a time value that contains decimal seconds. For example, this problem occurs if your document contains a time value that is in the following format:
HHMMSSDD
According to the HIPAA documentation about the Time field, this time format is correct. However, this time format causes parse errors or translation errors in the BizTalk Accelerator for HIPAA version 3.0. If you use a time format of HHMMSS, your document is processed successfully.
This problem occurs because the BizTalk Accelerator for HIPAA version 3.0 Microsoft SQL Server 2000 tables contain an incorrect definition of the HIPAA TM data type.
Reference LinksEvent ID 24 is logged and you receive parse error messages or translation error messages

Catch threats immediately

We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.

See what we caught

Did this information help you to resolve the problem?

Yes: My problem was resolved.