Event ID - 24800

Event Id24800
SourceCPQCISSE
DescriptionLogical drive 2, configured on Array Controller in slot 1, returned a fatal error on a read/write request on the volume.
Logical block address 84c1b54f, block count 128, command 28, drive bus 1 and Drive Id 1.
Event Information
This message from newsgroup may help you:
--------------------------------------------------------------------------------
It sounds like the OS is not able to get the proper response for all its data access in the logical drive(S). The reson could be one of this
1. The driver for the raid controller for the OS you having is not current
2. The firmware on the array controller is not current
3. The firmware on the Hard drives might no be current
4. The driver and firmware for the scsi adapter, where the tape device is hooked in to, is not Current

Best be will be to to update all this things and see if that clears the issue away before you suspect a physical hardware error

NOTE:
When you update firmware(ofline option only) and driver, make sure you update the drivers first because you update a firmware on a controller (The reason why is, if you update the firmware before driver is updated when you reboot the server after firmware update with still an old driver, the driver might not understand/smoothly communicate with the controller which might prevent the server to boot to the OS)
--------------------------------------------------------------------------------.
Reference LinksEvent Id: 24800 Event Source: CPQCISSE

Catch threats immediately

We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.

See what we caught

Did this information help you to resolve the problem?

Yes: My problem was resolved.
No: The information was not helpful / Partially helpful.