Event ID - 24586

Event Id24586
SourceCPQCISSE
DescriptionDrive Array Controller Failure (Slot 0)
Event Information
This message from newsgroup may help you:
--------------------------------------------------------------------------------
You need to get HP to replace the 641 controller. This behaviour has been seen on the 6402/6404 controllers but not the 641 (As far as I know). Are you sure it isn't a 6402 controller?

Please log a call with HP and get them to replace the controller. The disk configuration will be picked up by the new controller OK as it's held on the disks.

If this is a 641 controller, the spare part number required (which includes a 64Mb cache module) is 305414-001. If you have the larger 128Mb cache installed this has to be swapped over to the new controller by the engineer.

If this is in fact a 6402 controller, the spare part number required is 309520-001. This is the bare module. Additonal cache and batteries have to be swapped over on to the replacement from the original controller.

When logging the call with HP quote Engineering Advisory (Internal document) EX050324_EW01 and ask for the part number above (Whichever is correct).
--------------------------------------------------------------------------------.