Event ID - 23

Event Id23
SourceBizTalk Server 2004
DescriptionError encountered: ERROR (62), docnr 10017 : The length of the element is not correct. Contact the sender. target format: [5 00401 ], document: [852 004010DEFAULT X ], segment: [#5:SE ], element: [#1: 96:Number of included segments], Integer part exceeds the maximum of 6 digits, value: [1157980]
Event InformationAccording to Microsoft:
CAUSE:
This problem occurs if you submit an EDI document that has more than 999,999 segments. The BizTalk Server 2004 Base EDI Adapter has a limitation where it cannot process a document that has more than 999,999 segments.
RESOLUTION:
A supported hotfix is now available from Microsoft, but it is only intended to correct the problem. Only apply it to systems that are experiencing this specific problem.
Reference LinksFIX: Event ID 23 is repeatedly logged in the Application log on a computer that is running BizTalk Server 2004

FIX: The Base EDI Adapter does not process a large EDI message and Event ID 23 is logged in the Application log in BizTalk Server 2004