Event Id | 230 |
Source | SNA Server |
Description | Connection |
Event Information | According to Microsoft : CAUSE • Autocreate controller (AUTOCRTCTL), which is configured in the AS/400 Line Description, is set to No and you are using the incorrect Local Node ID value for the controller you have manually created on the AS/400. • The Remote SAP Address in the SNA Server connection properties is different than the SSAP address in the AS/400 line description. NOTE: The SAP address defined in the SNA Server link service setup does not have to match anything on the AS/400. • The administrator configured the Remote Network Address using an address that already exists on the LAN (and is bound to the DLC protocol) but it is not the address that the AS/400 administrator is attempting to connect to. For example, an administrator used the SNA Server machine address or other Windows NT machine that has the MS-DLC protocol installed. RESOLUTION To resolve this problem, use one of the following methods: • Reconfigure the controller on the AS/400 to match the desired parameters. • Delete the controller on the AS/400 and allow it to auto- create. • Match the Control Point Name of the SNA Server using the SNA Manager only if the Control Point Name is not in use by any other device. |
Reference Links | Event ID: 56 with Distributed Link Services to AS/400 |