Event ID - 2123

Event Id2123
SourceStorageManagement
DescriptionRedundancy lost
Event InformationAccording to Dell :

Cause:
A virtual disk or an enclosure has lost data redundancy. In the case of a virtual disk, one or more array disks included in the virtual disk have failed. Due to the failed array disk or disks, the virtual disk is no longer maintaining redundant (mirrored or parity) data. The failure of an additional array disk will result in lost data. In the case of an enclosure, more than one enclosure component has failed. For example, the enclosure may have suffered the loss of all fans or all power supplies.

Resolution:
Identify and replace the failed components. To identify the failed component, select the Storage object and click the Health subtab. The controller status displayed on the Health subtab indicates whether a controller has a failed or degraded component. Click the controller that displays a Warning or Failed status. This action displays the controller Health subtab which displays the status of the individual controller components. Continue clicking the components with a Warning or Health status until you identify the failed component. See the online help for more information. See the enclosure documentation for information on replacing enclosure components and for other diagnostic information.
Reference LinksEvent ID 2123 of Source StorageManagement

Catch threats immediately

We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.

See what we caught

Did this information help you to resolve the problem?

Yes: My problem was resolved.
No: The information was not helpful / Partially helpful.