Description | An internal MTA error occurred. The MTA was unable to convert the incoming message <message id>. Isolation Layer (IL) result code: <error code>. Object at fault: <object name>. [<value> <value> <value> <value>] (14) |
Event Information | The message transfer agent (MTA) database may be corrupted. To help Microsoft Product Support Services track down the problem, create log files. For more information, see Knowledge Base articles Q163032 and Q168906 for more information. To create Ap*.log files, in the Diagnostics Logging tab of the Server Properties dialog box, select MSExchangeMTA and set the logging level of the Interoperability and Interface categories to Maximum. To create Bf*.log files, set the logging level of the APDU and X.400 Service categories to Maximum. |
Reference Links | Product: Exchange Version: 6.5.6940.0 Source: MSExchangeMTA ID: 207 |