Event Id | 1 |
Source | Microsoft Project Server Tracing Event log Provider |
Description | Automation error The server process could not be started because the configured identity is incorrect. Check the username and password. |
Event Information | According to Microsoft: CAUSE: This issue may occur if there is an issue with the user account that is configured as the identity for COM+ applications in Microsoft Project Server 2002. RESOLUTION: Method 1: Install the latest version of MDAC. Method 2: Verify that the IIS Lockdown Tool or the URLScan tool is configured correctly. Method 3: Verify that the correct permissions are set on the ViewDrop folder. Method 4: Specify the correct information for the user account that is configured as the identity for COM+ applications. Method 5: Reset the DSN. Method 6: Configure the correct value for the DSN registry entry. Method 7: Restart the Microsoft Project Server Views Notification Service. |
Reference Links | You receive a "There is no information to display in this view" error message when you try to access a Project view in Microsoft Project Server 2003 or in Microsoft Project Server 2002 You cannot build an OLAP cube when scheduled in Microsoft Project Server 2002 You receive a "There is no information to display in this view" error message when you try to view a project in Microsoft Project Server 2002, and "0x8000401a" error messages are logged in the Application log Description of the Project 2003 post-Service Pack 1 hotfix package: February 10, 2005 Description of the Microsoft Office Project Server 2003 post-Service Pack 1 hotfix package: March 18, 2005 |
Catch threats immediately
We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.