Event ID - 1465

Event Id1465
SourceActive Directory
DescriptionThe task that monitors the Directory Service for changes in the site topology for the Inter-Site Transport object %1 failed with the following status: %2 Additions- deletions- and modifications of the site topology beneath the Inter-Site Transport object will not be reflected in the configuration of the Inter-Site Messaging Service until its service is restarted or this machine is rebooted. The record data is the status code.
Event InformationCAUSE:
The task that monitors Active Directory for changes in site topology could not monitor the specified intersite transport object. Additions, deletions, and modifications of intersite transport objects will not be recognized by the Intersite Messaging service until this service is stopped and then restarted.

RESOLUTION:
Restart the Intersite Messaging service or the domain controller.
Reference LinksMicrosoft product: Windows Operating System Version: 5.0 Event Source: Active Directory Event ID: 1465