Event Id | 1198 |
Source | MSExchangeMTA |
Description | An error occurred while processing an association to entity. Presentation error: state check failure. Current state 0, service type 20, service flavor 2 Control block index 3. The association will be terminated and restarted if necessary. [PLATFORM KERNEL 27 108] (14) |
Event Information | According to Microsoft: CAUSE : This behavior can occur if you use Fully Qualified Domain Names (FQDN) or NetBIOS names to configure the connectors. RESOLUTION : To resolve this behavior, on both Exchange servers, configure the X.400 Connector to use the IP address of the remote MTA, and then restart both MTAs. |
Reference Links | XCON: Mail Not Flowing Through X.400 Connectors and Events 4282, 4283, 4284, 4287, 1209, and 1198 Occur |