Event Id | 1057 |
Source | CiscoUnity_NodeMgr |
Description | Snapshot file 1 busy, file replication cycle skipped. |
Event Information | According To Cisco: The defect CSCsa98269 is submitted to provide further information in this warning message. That additional information is: The default file replication cycle is set to 10 minutes. In some scenarios where there are a large number of greetings and voicenames, 10 minutes is not enough time to allow for file replication between the failover and secondary server. The following steps increase the failover file replication interval, allowing for all files to be copied to the failover system: -Open the Failover Monitor from the Start\Programs\Unity menu. -Click the 'Configure' button. -Increase the File Replication interval setting. This change takes effect immediately. Increasing the File Replication interval incrementally (by minute) will help determine the optimal file replication interval setting. |
Reference Links | Cisco Events Guide |