Event ID - 1032

Event Id1032
SourceCiscoUnity_Notifier
Description"Failed to set message waiting lamp for %1, ext %2, reason: Load from Doh failed. Turn on Doh diagnostics to troubleshoot. Failed to set message waiting lamp for %1, ext %2, reason: Load from Doh failed. Turn on Doh diagnostics to troubleshoot."
Event InformationAccording to Cisco:
Resolution:

This error message appears when the defect CSCeg02287 or CSCeg82723 is experienced. Unity 4.0(4) Engineering Specials 58 and 76 are available from TAC for the respective defects to correct this issue. Although the MWI lamp status is correct, the SA may also display an incorrect status for the affected subscriber.
Reference LinksEVT_MSG_MWI_FAILURE_DOH_LOAD