Event ID - 3

Event ID3
SourceNortonAntivirus for Gateways
DescriptionError: "bind" to (0.0.0.0).25 failed, error 10048 Data: Bytes: 0000: 40 27 00 00
Event InformationAccording to Symantec

Cause:

This error occurs when two differing services, for example an ISA server and NAVGW, attempt to use the same port. NAVGW tries to bind to port 25 (default) and gets the first error with a reference to "bind," and then goes away. The attempt by NAVGW to bind disrupts the ISA control over the port. A reboot repeats this cycle.

Resolution:

1.Install NAVGW to its own server.

2.Change the port the ISA server or NAVGW uses.
Reference LinksEvent ID 3 of Source Norton Antivirus for Gateways

Catch threats immediately

We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.

See what we caught

Did this information help you to resolve the problem?

Yes: My problem was resolved.
No: The information was not helpful / Partially helpful.