Event Id | 2123 |
Event Source | Server Administrator |
Description | Redundancy lost |
More Information | Cause : A virtual disk or an enclosure has lost data redundancy. In the case of a virtual disk, one or more physical disks included in the virtual disk have failed.Due to the failed physical disk or disks, the virtual disk is no longer maintaining redundant (mirrored or parity) data.The failure of an additional physical disk will result in lost data. In the case of an enclosure, more than one enclosure component has failed. For example, the enclosure may have suffered the loss of all fans or all power supplies. Resolution : Identify and replace the failed components. To identify the failed component, select the Storage object and click the Health subtab. The controller status displayed on the Health subtab indicates whether a controller has a failed or degraded component. Click the controller that displays a Warning or Failed status. This action displays the controller Health subtab which displays the status of the individual controller components. Continue clicking the components with a Warning or Health status until you identify the failed component. |
Reference Links |
Catch threats immediately
We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.