Event Id | 2056 |
Event Source | Server Administrator |
Description | Virtual disk failed. |
More Information | Cause : This event is logged when One or more physical disks included in the virtual disk have failed.If the virtual disk is non-redundant (does not use mirrored or parity data)then the failure of a single physical disk can cause the virtual disk to fail. If the virtual disk is redundant then more physical disks have failed than can be rebuilt using mirrored or parity information. Resolution : Create a new virtual disk and restore from a backup. Controller, rebuild the virtual disk by first configuring a hot spare for the disk, and then initiating a write operation to the disk. The write operation will initiate a rebuild of the disk. |