Event Id | 753 |
Event Source | Dell PowerVault |
Description | Physical device failed to start |
More Information | According to Dell: Cause: Drive failed to spin up during controller bootup Resolution: Check that the new array disk is seated properly. If not, remove and reinsert the disk. If the problem persists, see the Dell PowerVault 660F and 224F Storage Systems Installation and Troubleshooting Guide on how to troubleshoot the Fibre Channel hard disk drives. When completed, go to the Array Manager console and click to expand the Arrays storage object, right-click the PV660F Subsystem storage object, and select Rescan. This action will update the array disk status within the GUI. |
Reference Links | event id :753 and source :Dell PowerVault |