Event Id | 828 |
Event Source | Dell PowerVault |
Description | Enclosure access is Critical |
More Information | According to dell: Cause: The LS module connection may be broken or the management hardware is bad. LS modules are cards installed in slots at the front of the enclosure. Each LS module has an SES processor that monitors environmental functions and a Loop Redundancy Circuit (LRC) function, which maintains the viability of the Fibre Channel loop Resolution: Check to see that the LS module is enabled. Follow the Dell PowerVault 660F and 224F Storage Systems Installation and Troubleshooting Guide for troubleshooting an LS module. For part replacement, see the Dell PowerVault 660F and 224F Storage Systems Service Manual. After resolving the hardware problem and providing corrective action, go to the Array Manager interface and click to expand the Arrays storage object, right-click the PV660F Subsystem storage object, and select Rescan. This action will update the enclosure status within the GUI. |
Reference Links | event id:828 and source: Dell PowerVault |