Event Id | 825 |
Event Source | Dell PowerVault |
Description | Temperature is above working limit. |
More Information | According to dell: Cause: The room temperature is high. A fan is bad Resolution: Check all fans to see whether they are functioning properly. If yes, check that the ambient temperature is within limit. If necessary, adjust the room temperature. If the problem persists, power-cycle the system. If this does not solve the problem, replace the affected Advanced Cooling Module (ACM). See the Dell PowerVault 660F and 224F Storage Systems Installation and Troubleshooting Guide for information on how to troubleshoot the ACM. See the Dell PowerVault 660F and 224F Storage Systems Service Manual for part replacement procedures. After fixing the temperature problem, go to the Array Manager console and click to expand the Arrays storage object, right-click the PV660F Subsystem storage object, and select Rescan from the context menu that comes up. This action will update the temperature and/or the fan status within the GUI. |
Reference Links | event id:825 and source: Dell PowerVault |
Catch threats immediately
We work side-by-side with you to rapidly detect cyberthreats
and thwart attacks before they cause damage.