Event ID - 857

Event Id857
Event SourceDell PowerVault
DescriptionWarm boot failed
More InformationAccording to dell:
Cause:

A memory error was detected during the warm boot scan, which may result in possible data loss

Resolution:
Power cycle the PV660F subsystem
If the error persists:
Remove and reinsert the controller. If the controller fails to come online, contact customer service.
If needed, follow the procedures in the Dell PowerVault 660F and 224F Storage Systems Service Manual to replace the controller module.
Reference Linksevent id:857 and source: Dell PowerVault