Event ID - 591

Event Id591
Event SourcePercPro
DescriptionTemperature exceeded the maximum warning threshold.
More InformationAccording to Dell:
Cause:

The array disk enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot

Resolution:
Check for factors that may cause overheating. For example, verify that the enclosure fan is working. Youshould also check the thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot. Refer to the enclosure documentation for more diagnostic information.
Reference Linksevent id:591 and source:PercPro