Event ID - 586

Event Id586
Event SourcePerc2Pro
DescriptionSmart configuration change
More InformationAccording to Dell:
Cause:

A disk has received a SMART alert (predictive failure) after a configuration change. The disk is likely to fail in the near future

Resolution:
Replace the disk that has received the SMART alert. If the array disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing an array disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may cause data loss
Reference Linksevent id:586 and source:Perc2Pro