More InformationAccording to Dell:
Cause:

A physical disk has been removed from the array. This event can also be caused by loose or defective cables or by problems with the enclosure.

Resolution:
If a physical disk was removed from the array, either replace the disk or restore the original disk. You can identify which disk has been removed by locating the disk with a red "X" in the Array Manager console's tree view. Perform a rescan after replacing or restoring the disk. If a disk has not been removed from the array, then check for problems with the cables. Make sure that the enclosure is powered on. If the problem persists, check the enclosure documentation for further diagnostic information.
Reference Linksevent id:501 and source: Perc2Pro