Event Id | 529 |
Event Source | Perc2Pro |
Description | Virtual Disk check consistency cancelled |
More Information | According to Dell: Cause: The check consistency operation cancelled because a physical disk in the array has failed or because a user cancelled the check consistency operation. Resolution: If the physical disk failed, then replace the physical disk. You can identify which disk failed by locating the disk with a red "X" in the Array Manager console's tree view. Perform a rescan after replacing the disk. When performing a consistency check, be aware that the consistency check can take a long time. The time it takes depends on the size of the physical disk or the virtual disk |
Reference Links | event id:529 and source: Perc2Pro |