Event ID - 586

Event Id586
Event SourceVxSvc_Perc2Pro
DescriptionSmart configuration change.
More InformationThis information from some newsgroups may help you:
------------------------------------------------------------------------------
CAUSE:
A disk has received a SMART alert (predictive failure) after a configuration change. The disk is likely to fail in the near future.
ACTION:
Replace the disk that has received the SMART alert. If the array disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing an array disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may cause data loss.
------------------------------------------------------------------------------