Event Id | 589 |
Event Source | VxSvc_Perc2Pro |
Description | Smart warning degraded. |
More Information | This information from some newsgroups may help you: ------------------------------------------------------------------------------ CAUSE: A disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail in the near future. ACTION: Replace the disk that has received the SMART alert. If the array disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing an array disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may cause data loss. ------------------------------------------------------------------------------ |
Reference Links |