Event Id | 571 |
Event Source | VxSvc_PercPro |
Description | PERC 2/DC Controller 0, Array Disk 1:12 Sense Key = <key>, Sense Code = <code>, Sense Qualifier = 0. |
More Information | This information from Newsgroups may help: ------------------------------------------------------------------------------ CAUSE: Problem when I update the BIOS. RESOLUTION: If this disk is part of a redundant virtual disk, select the Offline option and then replace the disk. Then configure a hot spare and it will start the rebuild automatically. If this disk is a hot spare, select the Prepare to Remove option and then replace the disk. If this disk is part of a non-redundant disk, you should back-up your data immediately. If the disk fails, you will not be able to recover the data. |